In this Hytrol How-To, you will learn how to reset all EZLogic® zones to ABEZ default settings.
First, connect the push button programmer to the discharge controller. Push and hold down both buttons for over one second. Next, press the left button seven times. This will prompt the green LED to flash eight times. Then press the right button one time, and after a series of flashes, the red LED will turn on and stay on. Then, press the left button three times, which will prompt four green flashes.
After that, press the right button one time and after a series of flashes, the amber LED will turn on and remain on. Lastly, press and hold down both buttons simultaneously for over one second.
This will reset all EZLogic® controllers to ABEZ default settings.